Awka, Anambra State, Nigeria; www.suchnetcomsolar.com; Tel: (+234) 08171968872; [email protected]; [email protected]
Suchnetcom Solar LTD ('Our Youth Skill Development Training on PV Solar Installation on its Way )
Head Office:
Suite 5, Fab Anieh House, 89 Club Street (former Abakaliki Street), Awka, Anambra State Capital, Nigeria.
Tel: (+234) 08171968872, 08132643723;
Email: [email protected];
FB: suchnetcom.solar; TW: SNCS_Ltd; Skype: suchnetcom
Battery | Charge Controller | Container Power Plant | Inverter | LED Lights| Solar Panel | Stabilizer | Solar Lantern | Sunking and DLight Solar Lanterns | Solar Water Heater | Solar Streetlight | Micro Wind turbine (MWT) | Plug-and-Play Solar Power Generator(PPSPG) | Transient Voltage Surge (TVSS) | Surge Protection Devices (SPD) | HSPGS Powered Streetlight
Contact us here
Contact us here
Head Office: Suite 5, Fab Anieh House, 89 Club Street (former Abakaliki Street), Awka, Anambra State Capital, Nigeria.
Tel: (+234) 08171968872, 08132643723;
Email: [email protected];
FB: suchnetcom.solar; TW: SNCS_Ltd; Skype: suchnetcom
Surge Protective Device
Surge Protective Device
Price: ₦ 19,000 (Excl VAT)
Technical Specifications:
- Model Number: BT Y PVM 150 RM
- Max. PV voltage [ Ucpv ]: ≤150V
- Short-circuit current rating (EN50539-11)
[Isc pv]: 1000A
- Max. Continuous D.C. Voltage
(DC+/DC- → PE) [Uc): 75V
- Total discharge current (8/20) [Itotal]:
40kA
- Nominal discharge current (8/20)
(DC+/DC- → PE) [In]: 20kA
- Max. Discharge current (8/20)
(DC+/DC- → PE) [Imax]: 40K
- Voltage protection level at In [Up]: ≤0.8KV
- Voltage protection level at 5kA
[Up]: ≤0.6KV
- Response time [tA]: ≤25ns
- Operating temperature range [Tu]:
-40°C... +80°C
Surge Protective Device
Surge Protective Device
Price: ₦ 21,000 (Excl VAT)
Technical Specifications:
- Model Number: BT Y PVM 600 RM
- Max. PV voltage [ Ucpv ]: ≤600V
- Short-circuit current rating (EN50539-11)
[Isc pv]: 1000A
- Max. Continuous D.C. Voltage
(DC+/DC- → PE) [Uc): 300V
- Total discharge current (8/20) [Itotal]:
40kA
- Nominal discharge current (8/20)
(DC+/DC- → PE) [In]: 20kA
- Max. Discharge current (8/20)
(DC+/DC- → PE) [Imax]: 40K
- Voltage protection level at In [Up]: ≤2.5KV
- Voltage protection level at 5kA
[Up]: ≤2KV
- Response time [tA]: ≤25ns
- Operating temperature range [Tu]:
-40°C... +80°C
- Home
- About Us
- SKILL TRAINING
- Plug-and-Play Solar Generator
- 10KVA PPSPG (Plug and Play Solar Power Gen)
- Automatic Isolation Power Switching
- Project Overview
- Design Consultancy
- Solar Home System
- HSPGS Powered Streetlights
- Solar Energy Solution
- Project List
- Solar Borehole Pump
- Solar Streetlight
- SHOP SNCS LTD
- Surge and Signal Monitoring Devises
- Wind Turbine
- Careers
- Customer Care
- Transformers
- Datalink Communications
- Legal
- Knowledge Base
- Site Survey Form
- Feedbacks and Comments
- Technical Supports
- Contact Us
- Home
- About Us
- SKILL TRAINING
- Plug-and-Play Solar Generator
- 10KVA PPSPG (Plug and Play Solar Power Gen)
- Automatic Isolation Power Switching
- Project Overview
- Design Consultancy
- Solar Home System
- HSPGS Powered Streetlights
- Solar Energy Solution
- Project List
- Solar Borehole Pump
- Solar Streetlight
- SHOP SNCS LTD
- Surge and Signal Monitoring Devises
- Wind Turbine
- Careers
- Customer Care
- Transformers
- Datalink Communications
- Legal
- Knowledge Base
- Site Survey Form
- Feedbacks and Comments
- Technical Supports
- Contact Us
Labeled Diagram Model SNCS1.5K to SNCS10K PPSPG
Switching-Off Procedure for Model SNCS1.5K to SNCS10K
Switching-On Procedure for Model SNCS1.5K to SNCS10K
Labeled Diagram for SNCS300 and SNCS500 PPSPG
Switching-on Procedure for Model SNCS300 to SNCS500 PPSPG
Switching-off Procedure for Model SNCS300 to SNCS500 PPSPG
Transient Volatge Surge Suppressor (TVSS) - for DC Power
Transient Volatge Surge Suppressor (TVSS) - for DC Power
Transient Volatge Surge Suppressor (TVSS) - for AC Power
Transient Volatge Surge Suppressor (TVSS) - for AC Power